In 2014 it underwent significant upgrades. I have a Pit Boss vertical smoker and was getting the same error. Open the side panel of the hopper to access these wires. COPYRIGHT 2023. Save my name, email, and website in this browser for the next time I comment. Rent To Own Homes In Caribou Maine, The Five Biggest Sports Clubs In The World, read our comprehensive guide on how to fix Louisiana grill error codes, Rheem Tankless Water Heater Maintenance [Why+ How To Do], Rheem Tankless Water Heater Code 61 [Why+ How To Fix], Rheem Tankless Water Heater Code 14 [Why+ How To Fix], Rheem Tankless Water Heater Code 99 [Why+ How To Fix], Rheem Tankless Water Heater Code 76 [Why+ How To Fix]. When you buy through links on our site, we may earn an affiliate commission. However, it could also simply just be a bad connection that needs to be corrected. The warranty coverage Cooking with your Louisiana Wood error: Content is protected !! Press the TEMP button to indicate that the setpoint temperature is displayed, and press the Temperature Adjust Arrows to a minimum of 121C / 250F for 20 minutes. The digital display of your Louisiana Pellet Grill will flash some error codes like ER-1, ER-2, and others. Close the metal lid and turn off the smoker. Step 4: Inspect the igniter to determine whether it is heating up and is properly positioned. Sep 3, 2014 - This Pin was discovered by Wendy Fuchs. Plug in the grill and power it on to see if the fuse blows. We are a participant in the Amazon Services LLC Associates Program (Amazon.com), Rakuten.com, Impact.com and CJ.com affiliate advertising programs designed to provide a means for us to earn fees by linking to these affiliated sites. If a grease fire occurs, turn off the unit first and let it cool. Thanks. If the temperature readings between the heat gun and the controller board are way off, you likely have a bad sensor. I had a Louisiana as my first pellet cooker as well. $29.99. Pellet Grill vs. Charcoal Grill VS. Gas Grill: Everything You Need to Know The Pellet Grill Buying Guide for 2022 \"defaultusername\" spirits oppressively high. I just replaced my 3rd control board and sensor this last one worked for 15 min before it errored and stopped working!!! Err & Er1 Cause. Follow these steps to remove and replace the controller in your Louisiana Grills Estate.Step 1: Remove the phillips head screws holding the front panel of the grill in place.Step 2: Remove the back plate on the inside of the front panel.Step 3: Remove the temperature probe wire from the controller.Step 4: Disconnect the wiring harness from the controller and remove both nuts holding the controller in place.Now that you have removed your controller, lets get the new on on there and get this grill cookin'!Step 5: Secure the new controller with the two nuts.Step 6: Place the wiring harness and temperature probe wires back onto the new controller.Step 7: Screw the back place onto the back of the front panel.Step 8: Screw the front panel back on the grill and we are ready to fire it up!Stay connected with Louisiana Grills:Website: https://louisiana-grills.com/Instagram: https://www.instagram.com/louisianagrills/Facebook: https://www.facebook.com/LouisianaGrills However, the general process is similar for all Louisiana Grills products. Next, clean them evenly and put them back into their places. Z Grills Pellet Grill Error Codes Explained - YouTube Have your electrician make sure that the sensor probe wires are securely connected in ports 1 and 2 of Get wood-fired recipes, find out about Memphis events and new products, and read about how your Memphis community is cooking up something big. -Ensure that pellets are feeding into the fire pot and that the auger is turning. Customers will be subject to parts, shipping, and handling fees if unable to provide proof of the purchase or after the warranty has expired. Lastly, inspect the GFCI outlet. wills o' nats last of the summer wine. Dansonsrecommends the use of a grill cover when the grill is not in use. First, try to find out the main culprit behind the issue and then fix it following our solution guide on this problem. Amazon.com: Customer reviews: Louisiana Grills 60700-LG700 LG 700 Another possible reason that can cause the error code message ER-2 to flash on your smoker screen is that the grill wont stay lit at any temperature above 150 F. Fixing ER2 is an easy process. Next, check the fuse of the circuit board for a trip. If it does, then you need a new auger motor. All Right Reserved by FIREPLACEHUBS. Heating pellets may contain materials other than 100% hardwood, which can be harmful to your health. Location: Mountains of Colorado. I also have a bL2 code and dont know what the problem is. All Right Reserved by FIREPLACEHUBS. I have a Louisiana Grill, new at Christmas. $29.99. These aesthetic changes of the grill do not affect its performance. Louisiana 7 erL - Error Code - Smoking Meat Forums I distinctly remember shutting the grill down on last use as I only grilled some peppers for 5 minutes. You shouldnt unplug the power chord. Insufficient Airflow. Check the RTD connection by following these steps: Unplug the grill and remove the two Phillips head screws holding the controller in place. A great feature to have to get the best searing results on steaks etc. This error code will show up when the following things are wrong with your smoker. Warranty Information - Louisiana-Grills However, other error codes will only appear on specific types of control panels which Ill note below. It can be a fiddly job, but its important to take your time and treat the spade connections on the wires with care. Step 3: Look for ash build-up or obstructions in the burn grate and pot. The ER-1 error message can have two causes behind it. I just called their customer service line and it works. More details . Step 3: Look for ash build-up or obstructions in the burn grate and pot. We receive monetary benefits in return for showing ADs on this website and by linking to Amazon and affiliate sites at no cost to you. If it doesnt work, take help from the owners customer support center. The flame broiler is used as both a grease pan and for an open flame cook.During normal cooks the flame broiler should remain closed, both to prevent fires and ensure proper grease draining. Therefore, youll need the wiring diagram from your manual. How to Replace the Controller in Your Louisiana Grills Estate - YouTube It is a self-diagnosis. Direct Grilling Explained; My order is delivered but I only received part of my order. Unplug the grill from the AC outlet and remove the pellets from the grill. The temp probe was my first thought. Fuel and airflow are other reasons. Louisiana grills LG900 User Manual - ManualMachine.com Also, a dirty or wet temperature probe can cause grill temperature problems. Check the auger motor connection to thecontrol board (yellow wires) and make sure it is secure. My LG 400 comes on but the igniter will not fire the pellets. Does something have to be reset? The auger wont move or rotate if it gets jammed by dirt and debris. This is great as youll know what the issue is without having to consult an electrician. Check that the connection between the Molex connectors is secure, if not, this could have been the cause of your Er1 error code. How to Prevent The ERH Code? Click here for this grill: https://amzn.to/36qzqHxAll good now. A typical scenario where a grease fire can occur is, lets say you have been smoking lots of fatty meats, brisket for instance, and you havent cleaned the grease tray. Pit Boss recommends cleaning the grill regularly, implementing the burn-off procedure after every cook, using the proper pellets, and caring for the probes properly. To ensure proper airflow, make sure that your Louisiana Grill is at least 36 away from combustible constructions, all back vents are unobstructed, and that the fan is clean. Well, check both of the issues & fix them(what you find) following our instructions in the article. The fact that this unit has three cooking compartments means that it can do just about anything. There is much debate within the BBQ world about whether pellet grills/smokers can cook a good steak. Product: https://www.lifetime.com/lifetime-91025-smoker-grillGive us a follow on social media! Combine meat, How to Fix The Er1 Code on Pit Boss? In order to fix the ERR code, check the wiring of the RTD probe into the controller. Step 3: Look for ash build-up or obstructions in the burn grate and pot. The fan of your Louisiana Grill will not turn if the wire connection from the fan to the control gets damaged or loose. OWNER RICK'S APPLIANCE REPAIR APPLIANCE TECHNICIAN FOR 31 YEARS REFRIGERATION SPECIALIST ONLINE SERV TECH: ApplianceBlog.com You should turn off the grill and unplug it when the grills fan stops running. If the fuse doesnt blow, unplug the grill and connect the auger motor (yellow) wires. So I ordered a "replacement" temperature probe as mentioned on another thread in the forum. Open the main barrel lid. Even with these safeguards, the protective coatings can be compromised by various substances and conditions beyondDansons' control. This is where a grease fire will typically occur. Louisiana Pellet Grill Troubleshooting [5 Easy Solutions], 3. Please help. The consent submitted will only be used for data processing originating from this website. Any suggestions on what might fix this? 1200 Black Label Series Grill with WiFi Control. If cleaning doesnt work, check the wiring connections & fix them if you get them defective. While I have my main article on the best vertical pellet smokers, that article covers all brands. -If the flame broiler is placed properly you should see it at an angle, higher on the left side and lower on the right. 1. Returned one only to have the same issue with the second and customer service was useless after being on hold for an hour. Louisiana Grills is a well-known manufacturer of high-quality pellet grills and smokers. Therefore, the incorrect startup can also be the culprit to get a consistent cooking temperature. The best way to prevent the ErH code or other issues is to ensure youre following the Pit Boss care and maintenance recommendations. Also, check the fuse & replace it if needed. Check the RTD connection by following these steps: Turn off and unplug your grill. -Check for an augerjam. louisiana grills error code er 1 how to reset Expired Louisiana Grills promo codes These probably won't work but give them a try! Yes, its normal. Pokud budete nadle prohlet nae strnky pedpokldme, e s pouitm cookies souhlaste. Then close the lid and adjust your temperature to the desired setpoint. Louisiana Pellet Grill Troubleshooting [5 Easy Solutions] - FireplaceHubs Here, you can watch the video given below on the Lousiana grill cleaning as proper cleaning can prevent various issues with your grill. After months of attempting to make it cook correctly (with factory "help") I finally dumped it and went with an FEC-100 then later a PG-1000 and have never been happier. Ever since then, after grilling, the fan wont shut off after cool down, any suggestions? The grill will produce smoke while the start-up cycle is taking place. Disconnect the three components from the control board (auger motor: yellow wires, fan motor: blue wires, and igniter: red wires). Now, for many years Louisiana Grills have been fitting flame broilers to their pellet grills. If you would like to learn more about all the wood pellet grills/smokers on the market today and their differences I think you will find my wood pellet grill guide useful. If it is loose, tighten it, and this may solve the issue. Had to take off the housing and pull Live Chat +1(978) 822-0999 Email WhatsApp. Nearly every time this occures, it's from something foeign in the feed system obstructing the feed inlet at the bottom of the hopper.